Contents
The NS-2™ contents illustrates the range of inspections and inspection techniques required.
Hyperlinks allow quick access between specificaitons and sub-specification when required.
List of Drilling Equipment
- Abandonment Tools
- Drill Collar
- Drill Pipe - Aluminium
- Drill Pipe - Heavy Duty Landing String (HDLS)
- Drill Pipe - Heavy Weight (HWDP)
- Drill Pipe - Steel
- Drill Stem Subs
- Fishing Tools
- Hole Opener
- Hydroclean
- Jar - Drilling
- Kelly
- Kelly Valve
- MWD/LWD
- Milling Tools
- Motor - Drilling
- NM Flexi Collar
- Pup Joint, Drill Pipe
- Reamers - Roller
- Side Entry Subs
- Stabilisers
- Stabilisers - Adjustable
- Turbines
- Wired Drill Pipe
- Wired Heavy Weight Drill Pipe
- Wired Subs
List of Associated Equipment
- Cementing Tools
- Coring Equipment
- Crossovers, Coring and Tubular
- DST String
- DST Tools
- Gravel Pack Running Tools
- Inflatable Packers
- Integral Joint Tubing (TTRD)
- Lift Caps
- Lift Subs
- Liner Running Tools
- PBR Cleanout Tools
- Refurbished Bits
- Wellhead Running Tools
List of Additional Specs
- If Failure Occurs
- Inspection Frequencies
- Limited Service
- Receipt Inspection
- Repair Procedures
List of Sub-Specs
- Sub-Spec 001 - General Requirements
- Sub-Spec 002 - Cold Rolling
- Sub-Spec 003 - Visual and Dimensional Inspections
- Sub-Spec 004 - Magnetic Particle Inspection (MPI) (Connection)
- Sub-Spec 005 - Magnetic Particle Inspection (MPI) (Body, End Area)
- Sub-Spec 006 - Liquid Penetrant Inspection (Dye Pen)
- Sub-Spec 007 - UT Wall Thickness Measurement
- Sub-Spec 008 - Electromagnetic Inspection (EMI)
- Sub-Spec 009 - Ultrasonic Testing End Area (UTEA)
- Sub-Spec 009a - Ultrasonic Testing (Full Length)
- Sub-Spec 010 - Portable Hardness Testing
- Sub-Spec 011 - Pressure Test
- Sub-Spec 012 - Automated Thread Inspection (ATI) by Alternating Current Field Measurement (ACFM)
- Sub-Spec 013 - Electrical Conductivity
- Sub-Spec 014 - Outside Diameter (OD) Gauging
- Sub-Spec 015 - Internal Plastic Coating (IPC)
- Sub-Spec 016 - Hardbanding
- Sub-Spec 017 - Minimum Internal Upset (MIU)
- Sub-Spec 018 - Overheating Test
- Sub-Spec 019 - Cold Working
- Sub-Spec 020 - Connection Make Up
- Sub-Spec 021 - Grant Prideco GPDS, XT, XTM
- Sub-Spec 022 - Vam CDS, EIS, VAM Express
- Sub-Spec 023 - Tenaris DSTJ, WT
- Sub-Spec 024 - IntelliServ™ SOP 3.5.1.13 - Field Inspection of IntelliCoils
- Sub-Spec 025 - IntelliServ™ SOP 3.5.1.14 - Inspection of Installed Unused IntelliCoils
- Sub-Spec 026 - IntelliServ™ Electrical Inspection
List of Tables
- Table 1 - Requirement for Qualification of Inspection Personnel
- Table 2 - Inspection Equipment Calibration Frequency
- Table 3 - Bottomhole Assembly (BHA) Colour Code Classification Chart
- Table 4 - Drill Pipe Colour Code Classification Chart
- Table 5 - Requirements for Drill Pipe Inspection Reporting
- Table 6 - Requirements for BHA Inspection Reporting
- Table 7 - Liquid Penetrant Inspection Dwell Requirements
- Table 8 - Ultrasonic Wall Thickness Instruments Performance Requirements
- Table 9 - Used Tool Joint Dimensional Acceptance Criteria
- Table 10 - Used Drill Pipe and Tool Joint Classification Chart
- Table 11 - Bending Strength Ratio
- Table 12 - Used HWDP and Connection Dimensional Acceptance Criteria
- Table 13 - Used BHA Connection Dimensional Acceptance Criteria
- Table 13a - Bevel Diameters on BHA Bit Box Connections
- Table 14 - Thread Types and Rolling Parameters
- Table 15 - Abandonment Tools Acceptance/Rejection Criteria
- Table 16 - Dimensional Criteria for Measurements of Drill Collar OD, Elevator and Slip Groove Recess
- Table 17 - Used Tool Joint Dimensional Acceptance Criteria Rev. 2 (Drill Pipe - Aluminium)
- Table 18 - Minimum Length for Drill String Subs
- Table 19 - Normal Float Lengths
- Table 20 - Float Up Lengths
- Table 21a - Used Tool Joint Acceptance Criteria - NOV Grant Prideco HI Torque
- Table 21b - Used Tool Joint Acceptance Criteria - NOV Grant Prideco eXtreme™ Torque
- Table 21c - Used Tool Joint Acceptance Criteria - Grant Prideco XT-M™
- Table 21d - Used Tool Joint Acceptance Criteria - Grant Prideco Double Shoulder™
- Table 21e - Used Tool Joint Acceptance Criteria - Grant Prideco uXT Connections
- Table 21f - Used Tool Joint Acceptance Criteria - Grant Prideco uDS Connections
- Table 21g - Used Tool Joint Acceptance Criteria - Grant Prideco TurboTorque™
- Table 21h - Used Tool Joint Acceptance Criteria - Grant Prideco TurboTorque™-M
- Table 22a - Dimensional Requirements for VAM® CDS™ Connections
- Table 22b - Dimensional Requirements for VAM® EIS™ Connections
- Table 22c - Dimensional Requirements for VAM® Express™ Connections
- Table 23 - Dimensional Requirements for Tenaris WT™ Connections
- Table 24 - Dimensional Requirements for Maximum Counterbore Diameter - Tenaris WT™
- Table 25 - Dimensional Requirements for DSTJ™ Connections
- Table 26 - Drill Pipe Wall Thickness